Thin Floor Cable

Ultra Thin Single Core Cable: PTFE


Single core heating cable is a coaxial cable with Copper braiding & high temperature PTFE thin jacket which makes the cable thinner. Single core heating are suitable for light flooring; IEC 60800 compliant

Heating Conductor Single strand/Multi-strand
Insulation PTFE
Shielding Tin Plated Copper Braiding
Outer Jacket PTFE
Cable dia. 2.5 mm
Cold Tails 3.5 m, Separate on both ends
Linear Wattage 11 W/m

Product Specifications
WHITE Wattage Cable Resistance
Code `@230V Length (m) Ohms
WSHCP-11- 013 150 13.5 352.67
WSHCP-11- 018 200 18.0 264.50
WSHCP-11- 022 250 22.0 211.60
WSHCP-11- 027 300 27.0 176.33
WSHCP-11- 032 350 32.0 151.14
WSHCP-11- 036 400 36.0 132.25
WSHCP-11- 045 500 45.0 105.80
WSHCP-11- 054 600 54.0 88.17
WSHCP-11- 063 700 63.0 75.57
WSHCP-11- 072 800 72.0 66.13
WSHCP-11- 082 900 82.0 58.78
WSHCP-11- 091 1000 91.0 52.90
WSHCP-11- 113 1250 113.0 42.32
WSHCP-11- 136 1500 136.0 35.27
WSHCP-11- 160 1750 160.0 30.23
WSHCP-11- 182 2000 182.0 26.45
WSHCP-11- 227 2500 227.0 21.16
WSHCP-11- 272 3000 272.0 17.63

Ultra Thin Single Core Cable: ETFE


Single core Heating Cable with high crush resistance; IEC 60335-2-96 compliant

Heating Conductor Single strand/Multi-strand
Insulation ETFE
Shielding Tin Plated Copper Braiding
Outer Jacket High Temp. PVC
Cable dia. 2.7 mm
Cold Tails 3.5 m, Separate on both ends
Linear Wattage 11 W/m

Product Specifications
WHITE Wattage Cable Resistance
Code `@230V Length (m) Ohms
WSHCE-11- 013 150 13.5 352.67
WSHCE-11- 018 200 18.0 264.50
WSHCE-11- 022 250 22.0 211.60
WSHCE-11- 027 300 27.0 176.33
WSHCE-11- 032 350 32.0 151.14
WSHCE-11- 036 400 36.0 132.25
WSHCE-11- 045 500 45.0 105.80
WSHCE-11- 054 600 54.0 88.17
WSHCE-11- 063 700 63.0 75.57
WSHCE-11- 072 800 72.0 66.13
WSHCE-11- 082 900 82.0 58.78
WSHCE-11- 091 1000 91.0 52.90
WSHCE-11- 113 1250 113.0 42.32
WSHCE-11- 136 1500 136.0 35.27
WSHCE-11- 160 1750 160.0 30.23
WSHCE-11- 182 2000 182.0 26.45
WSHCE-11- 227 2500 227.0 21.16
WSHCE-11- 272 3000 272.0 17.63

Thin Dual Core Cable


Floor Heating Cable are suited to generate heat under tile, wood or laminate floors in bathrooms, kitchens, entry-ways and sun rooms. Very thin construction makes them ideally suited for renovation of homes, apart from green-field construction. Single cold lead makes it even easier for installation.

Heating Conductor Single / Multi strand
Earth Conductor Multi-strand-Tin Plated Copper
Insulation PTFE/FEP/ETFE/XLPE
Shielding Poly. Al. Foil
Outer Jacket High Temp.PVC
Cable dia. 3.5 to 4.5 mm
Cold Tails 3.5 m, Separate Cold Lead
Linear Wattage 15.9 W/m

Product Specifications
Code `@230V Length (m) Ohms
WDUTHM-X-16-010 150 9.4 352.67
WDUTHM-X-16-014 225 14.2 235.11
WDUTHM-X-16-019 300 18.9 176.33
WDUTHM-X-16-024 375 23.6 141.07
WDUTHM-X-16-028 450 28.3 117.56
WDUTHM-X-16-033 525 33.0 100.76
WDUTHM-X-16-038 600 37.7 88.17
WDUTHM-X-16-043 675 42.5 78.37
WDUTHM-X-16-047 750 47.2 70.53
WDUTHM-X-16-057 900 56.6 58.78
WDUTHM-X-16-066 1050 66.0 50.38
WDUTHM-X-16-021 1200 75.5 44.08
WDUTHM-X-16-022 1350 84.9 39.19
WDUTHM-X-16-023 1500 94.3 35.3

.