Ultra Thin Single Core Cable: PTFE
Single core heating cable is a coaxial cable with Copper braiding & high temperature PTFE thin jacket which makes the cable thinner. Single core heating are suitable for light flooring; IEC 60800 compliant
Heating Conductor |
Single strand/Multi-strand |
Insulation |
PTFE |
Shielding |
Tin Plated Copper Braiding |
Outer Jacket |
PTFE |
Cable dia. |
2.5 mm |
Cold Tails |
3.5 m, Separate on both ends |
Linear Wattage |
11 W/m |
Product Specifications
WHITE |
Wattage |
Cable |
Resistance |
Code |
`@230V |
Length (m) |
Ohms |
WSHCP-11- 013 |
150 |
13.5 |
352.67 |
WSHCP-11- 018 |
200 |
18.0 |
264.50 |
WSHCP-11- 022 |
250 |
22.0 |
211.60 |
WSHCP-11- 027 |
300 |
27.0 |
176.33 |
WSHCP-11- 032 |
350 |
32.0 |
151.14 |
WSHCP-11- 036 |
400 |
36.0 |
132.25 |
WSHCP-11- 045 |
500 |
45.0 |
105.80 |
WSHCP-11- 054 |
600 |
54.0 |
88.17 |
WSHCP-11- 063 |
700 |
63.0 |
75.57 |
WSHCP-11- 072 |
800 |
72.0 |
66.13 |
WSHCP-11- 082 |
900 |
82.0 |
58.78 |
WSHCP-11- 091 |
1000 |
91.0 |
52.90 |
WSHCP-11- 113 |
1250 |
113.0 |
42.32 |
WSHCP-11- 136 |
1500 |
136.0 |
35.27 |
WSHCP-11- 160 |
1750 |
160.0 |
30.23 |
WSHCP-11- 182 |
2000 |
182.0 |
26.45 |
WSHCP-11- 227 |
2500 |
227.0 |
21.16 |
WSHCP-11- 272 |
3000 |
272.0 |
17.63 |
Ultra Thin Single Core Cable: ETFE
Single core Heating Cable with high crush resistance; IEC 60335-2-96 compliant
Heating Conductor |
Single strand/Multi-strand |
Insulation |
ETFE |
Shielding |
Tin Plated Copper Braiding |
Outer Jacket |
High Temp. PVC |
Cable dia. |
2.7 mm |
Cold Tails |
3.5 m, Separate on both ends |
Linear Wattage |
11 W/m |
Product Specifications
WHITE |
Wattage |
Cable |
Resistance |
Code |
`@230V |
Length (m) |
Ohms |
WSHCE-11- 013 |
150 |
13.5 |
352.67 |
WSHCE-11- 018 |
200 |
18.0 |
264.50 |
WSHCE-11- 022 |
250 |
22.0 |
211.60 |
WSHCE-11- 027 |
300 |
27.0 |
176.33 |
WSHCE-11- 032 |
350 |
32.0 |
151.14 |
WSHCE-11- 036 |
400 |
36.0 |
132.25 |
WSHCE-11- 045 |
500 |
45.0 |
105.80 |
WSHCE-11- 054 |
600 |
54.0 |
88.17 |
WSHCE-11- 063 |
700 |
63.0 |
75.57 |
WSHCE-11- 072 |
800 |
72.0 |
66.13 |
WSHCE-11- 082 |
900 |
82.0 |
58.78 |
WSHCE-11- 091 |
1000 |
91.0 |
52.90 |
WSHCE-11- 113 |
1250 |
113.0 |
42.32 |
WSHCE-11- 136 |
1500 |
136.0 |
35.27 |
WSHCE-11- 160 |
1750 |
160.0 |
30.23 |
WSHCE-11- 182 |
2000 |
182.0 |
26.45 |
WSHCE-11- 227 |
2500 |
227.0 |
21.16 |
WSHCE-11- 272 |
3000 |
272.0 |
17.63 |
Thin Dual Core Cable
Floor Heating Cable are suited to generate heat under tile, wood or laminate floors in bathrooms, kitchens, entry-ways and sun rooms. Very thin construction makes them ideally suited for renovation of homes, apart from green-field construction. Single cold lead makes it even easier for installation.
Heating Conductor |
Single / Multi strand |
Earth Conductor |
Multi-strand-Tin Plated Copper |
Insulation |
PTFE/FEP/ETFE/XLPE |
Shielding |
Poly. Al. Foil |
Outer Jacket |
High Temp.PVC |
Cable dia. |
3.5 to 4.5 mm |
Cold Tails |
3.5 m, Separate Cold Lead |
Linear Wattage |
15.9 W/m |
Product Specifications
Code |
`@230V |
Length (m) |
Ohms |
WDUTHM-X-16-010 |
150 |
9.4 |
352.67 |
WDUTHM-X-16-014 |
225 |
14.2 |
235.11 |
WDUTHM-X-16-019 |
300 |
18.9 |
176.33 |
WDUTHM-X-16-024 |
375 |
23.6 |
141.07 |
WDUTHM-X-16-028 |
450 |
28.3 |
117.56 |
WDUTHM-X-16-033 |
525 |
33.0 |
100.76 |
WDUTHM-X-16-038 |
600 |
37.7 |
88.17 |
WDUTHM-X-16-043 |
675 |
42.5 |
78.37 |
WDUTHM-X-16-047 |
750 |
47.2 |
70.53 |
WDUTHM-X-16-057 |
900 |
56.6 |
58.78 |
WDUTHM-X-16-066 |
1050 |
66.0 |
50.38 |
WDUTHM-X-16-021 |
1200 |
75.5 |
44.08 |
WDUTHM-X-16-022 |
1350 |
84.9 |
39.19 |
WDUTHM-X-16-023 |
1500 |
94.3 |
35.3 |
.