FLRY-A
These are thin walled cables ideal for use in automotives where its reduced insulation thickness and higher temperature withstanding properties serves its application in complex wiring harnesses.
Share Product
These are thin walled cables ideal for use in automotives where its reduced insulation thickness and higher temperature withstanding properties serves its application in complex wiring harnesses.
Share Product
Standard | In accordance with ISO 6722. |
Voltage Rating | 60 V D.C.; 25 V A.C. (Suitable for 12 Volts and 24 Volts systems) |
Temperature range | -40°C to +105°C. |
Cable Construction | Soft annealed electrolytic copper Conductor construction according to ISO 6722 (Concentric conductor, Type A).PVC insulation, Cl. B to ISO 6722. |
Properties | The lead free, PVC polymer, offers excellent resistance to petrol, chemicals, and abrasion, and in addition is suitable for both low and high temperature applications. Flame retardant |
Packing | Available in 100 meters. Longer length available in spools. |
Nominal Cross-Section | No.of Strands | Max. Strand Diameter | Nominal Conductor diameter | Max. DC Conductor resistance at 20°C (Ω/km) | Nominal Insulation Thickness | Nominal Overall Diameter | |||||||||
mm2 | mm | mm | Plain Copper | Tinned Copper | mm. | mm. | |||||||||
0.22 | 7 | 0.21 | 0.7 | 77.9/- | 84.8/86.5 | 0.2 | 1.2 | ||||||||
0.35 | 7 | 0.26 | 0.8 | 47.8/- | 52.0/54.5 | 0.2 | 1.3 | ||||||||
0.5 | 19 | 0.19 | 1 | 34.1/- | 37.1/38.2 | 0.22 | 1.6 | ||||||||
0.75 | 19 | 0.23 | 1.2 | 22.7/- | 24.7/25.4 | 0.24 | 1.9 | ||||||||
1 | 19 | 0.26 | 1.35 | 17.0/- | 18.5/19.1 | 0.24 | 2.1 | ||||||||
1.5 | 19 | 0.32 | 1.7 | 11.7/- | 12.7/13.0 | 0.24 | 2.4 | ||||||||
2 | 19 | 0.37 | 2 | 8.66/- | 9.42/9.69 | 0.28 | 2.8 | ||||||||
2.5 | 19 | 0.41 | 2.2 | 7.0/- | 7.60/7.80 | 0.28 | 3 |