UL 3173

UL 3173

Product Code :   UL 3173

It is ideally suited for lighting equipment, motor and coil leads, transformers, control panels, military equipment, industrial controls, computers, electronic equipment wiring with higher temperature requirements. and appliance wiring applications These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack.

Share Product


Standard UL - Std. 758. Complies to CSA No. 22.2 210 and 127
Nominal Voltage 600Vac
Temperature Range -40°C to +125°C
Bending Radius Approx. 5 x cable &‌Oslash;
Conductor Size AWG 32 to AWG 10
Cable Construction
Conductor Solid or stranded Annealed Bare Copper (ABC)/Annealed Tinned Copper (TPC)
Insulation Cross Linked Polyethylene (XLPE)
Properties
Chemical resistant Excellent

Product Specifications

Conductor -Anealed Bare Copper (ABC) Insulation- XLPE Ampacity Net
Gauge No of Strand CSA Dia. Max.DC Resistance Thickness in mm Wire dia. of Wire Weight
Srands dia. in mm mm2 mm Ohms/km`@ 20°C Nom. Min. Nom., mm Amp. kg/km
AWG 26/7/34 7 0.16 0.14 0.49 132.9 0.76 0.68 2.01 1.4 4.5
AWG 24/7/32 7 0.20 0.22 0.61 85.1 0.76 0.68 2.13 2.2 5.5
AWG 22/17/34 17 0.16 0.34 0.77 54.7 0.76 0.68 2.29 3.4 7.1
AWG 20/16/32 16 0.20 0.50 0.93 37.2 0.76 0.68 2.45 5.0 9.0
AWG 19/24/33 24 0.20 0.75 1.14 24.8 0.76 0.68 2.66 7.5 11.8
AWG 18/17/30 17 0.254 0.86 1.21 21.7 0.76 0.68 2.73 8.6 13.0
AWG 16/26/30 26 0.254 1.32 1.50 14.2 0.76 0.68 3.02 13.2 18.0
AWG 15/30/30 30 0.254 1.52 1.61 12.3 0.76 0.68 3.13 15.2 20.1
AWG 14/40/30 40 0.254 2.03 1.86 9.2 0.76 0.68 3.38 20.3 25.5
AWG 12/65/30 65 0.254 3.29 2.38 5.7 0.76 0.68 3.90 32.9 38.5
AWG 10/85/30 65 0.32 5.22 2.99 3.6 0.76 0.68 4.51 52.2 58.0
AWG 9/104/30 84 0.32 6.75 3.40 2.8 0.76 0.68 4.92 67.5 73.2