ETFE Wires

ETFE Wires

Product Code :   UL 11537

ETFE is often chosen over PTFE or FEP due to its superior mechanical strength.It has excellent heat-age properties and can withstand high voltages. ETFE is a good choice for the aerospace,medical,nuclear & instrumentation industries.

Share Product


Conductor Solid or Multi-strand, (AWG 32-AWG 16)
Conductor material Annealed Bare Copper & Plated annealed Copper
Insulation ETFE (Tefzel)
Rated Voltage 300V
Temperature rating (-180°C to +150°C)
Approval UL-11537
Standard UL-758

Product Specifications

Conductor No of Strand Diameters in mm Cross Sectional D.C Resistance Insulated dia Ampacity
AWG Strands AWG Strand Conductor Area (mm2) Max.( Ohms) Nom. Amp.
32 1 32 0.203 0.20 0.03 584.9 0.80 0.30
32 7 40 0.08 0.25 0.04 538.0 0.85 0.30
30 1 30 0.254 0.25 0.05 373.6 0.85 0.50
30 7 38 0.102 0.31 0.06 330.9 0.91 0.50
28 1 28 0.32 0.32 0.08 235.4 0.92 0.70
28 7 36 0.127 0.38 0.09 213.5 0.98 0.70
26 1 26 0.40 0.40 0.13 150.6 1.00 1.50
26 7 34 0.16 0.48 0.14 134.5 1.08 1.50
26 19 38 0.102 0.51 0.16 121.9 1.11 2.00
24 1 24 0.51 0.51 0.20 92.7 1.11 2.00
24 7 32 0.203 0.61 0.23 83.6 1.21 2.00
24 19 36 0.127 0.64 0.24 78.6 1.24 2.00
22 7 30 0.254 0.76 0.35 53.4 1.36 3.00
22 1 22 0.64 0.64 0.32 58.8 1.24 3.00
22 19 34 0.16 0.80 0.38 49.6 1.40 3.00
20 1 20 0.81 0.81 0.52 36.7 1.41 5.00
20 7 28 0.32 0.96 0.56 33.6 1.56 5.00
20 19 32 0.203 1.02 0.61 30.8 1.62 5.00
18 1 18 1.02 1.02 0.82 23.2 1.62 8.00
18 7 26 0.404 1.21 0.90 21.1 1.81 8.00
18 19 30 0.254 1.27 0.96 19.7 1.87 8.00
16 1 16 1.28 1.28 1.29 14.7 1.88 10.00
16 19 29 0.287 1.44 1.23 15.4 2.04 10.00
16 37 32 0.203 1.42 1.20 15.8 2.02 10.00