VDE Approved - WIPE Hotwire Special

VDE Approved - WIPE Hotwire Special

It is a special heating cable with unique integrated cold tail (IVC). The advantage of IVC is, it makes the cable-joint water proof and gives uniform cable dia all over for easy installation on membranes.

Share Product


Heating Cable-10 Watt/m VDE Approved


It is heavy duty, low heat out put cable, mostly used for multi-functional building applications, stadiums, play grounds to keep them ready to use condition in all seasons.

Cable design Dual Core Cable with Return Wire
Heating Cond. Multi -strand
Insulation XLPE
Return Wire Multi-strand Tinned Copper
Shield Poly. Al. Foil
Sheath High Temperature PVC
Cold Lead 3.5 m, Integrated Cold tail
Cable dia. 6.5 mm
Linear Watt of Cable 10 W/m

Product Specifications
Item Wattage @ 230V Length Resistance
Code (m) (Ohms)
WISHCX 10 -010 100 10.0 529.0
WISHCX 10 -020 200 20.0 264.5
WISHCX 10 -030 300 30.0 176.3
WISHCX 10 -040 400 40.0 132.3
WISHCX 10 -050 500 50.0 105.8
WISHCX 10 -060 600 60.0 88.2
WISHCX 10 -080 800 80.0 66.1
WISHCX 10 -100 1000 100.0 52.9
WISHCX 10 -120 1200 120.0 44.1
WISHCX 10 -160 1600 160.0 33.1
WISHCX 10 -190 1900 190.0 27.8

Heating Cable-12.5 Watt/m VDE Approved


It is widely used and suitable for all type of flooring for indoor IVC and 100% EMI protection are its unique advantage.

Heating Conductor Multi-strand
Return Conductor Nickel Plated Copper
Earth Conductor Tin Plated Copper
Insulation PTFE
Shielding Poly. Al. Foil
Outer Jacket RTI High Temp.PVC
Cable dia. 5.0 mm
Cold Tails IVC, 3.5 m
Linear Wattage 12.5W/m

Product Specifications
Part Nos. Wattage @ 230V Length Resistance
(m) Ohms
WDHCP-13-012 150 12.0 352.7
WDHCP-13-018 225 17.9 235.1
WDHCP-13-024 300 23.9 176.3
WDHCP-13-030 375 29.9 141.1
WDHCP-13-036 450 35.9 117.6
WDHCP-13-042 525 41.8 100.8
WDHCP-13-048 600 47.8 88.2
WDHCP-13-054 675 53.8 78.4
WDHCP-13-060 750 59.8 70.5
WDHCP-13-072 900 71.7 58.8
WDHCP-13-084 1050 83.7 50.4
WDHCP-13-095 1200 95.6 44.1
WDHCP-13-107 1350 107.6 39.2
WDHCP-13-135 1700 135.5 31.1
WDHCP-13-163 2050 163.3 25.8
WDHCP-13-191 2400 191.2 22.0
WDHCP-13-215 2700 215.1 19.6
WDHCP-13-243 3050 243.0 17.3

In Slab Heating Cable-17 Watt/m VDE Approved


Heating cable has been specially designed for installing in cement floor in Halls, Lobbies etc.

Cable design Dual Core Cable with Return Wire
Heating Cond. Multi -strand
Insulation XLPE
Return Wire Multi-strand Tinned Copper
Shield Poly. Al. Foil
Sheath High Temperature PVC
Cold Lead 3.5 m, Integrated Cold tail
Cable dia. 6.5 mm
Linear Watt of Cable 17 W/m

Product Specifications
Item Wattage @ 230V Length Resistance
Code (m) (Ohms)
WISHCX 17 -009 150 8.8 352.7
WISHCX 17 -018 300 17.6 176.3
WISHCX 17 -024 400 23.5 132.3
WISHCX 17 -029 500 29.4 105.8
WISHCX 17 -035 600 35.3 88.2
WISHCX 17 -041 700 41.2 75.6
WISHCX 17 -050 850 50.0 62.2
WISHCX 17 -059 1000 58.8 52.9
WISHCX 17 -076 1250 73.5 42.3
WISHCX 17 -088 1500 88.2 35.3
WISHCX 17 -100 1700 100.0 31.1
WISHCX 17 -124 2100 123.5 25.2
WISHCX 17 -153 2600 152.9 20.3
WISHCX 17 -171 2900 170.6 18.2
WISHCX 17 -194 3300 194.1 16.0

Snow Melting-30 W/m VDE Approved


This Cable is specially designed for ice & snow melting outdoor applications, car parking, driveways, pavement, outdoor steps, ramps & drainage areas.

Cable design Dual Core Cable with Return Wire
Heating Cond. Multi -strand
Insulation XLPE
Return Wire Multi-strand Tinned Copper
Shield Poly. Al. Foil
Sheath High Temperature PVC
Cold Lead 3.5 m, Integrated Cold tail
Cable dia. 6.5 mm
Linear Watt of Cable 30 W/m

Product Specifications
Item Wattage @ 230V Length Resistance
Code (m) (Ohms)
WICHCX 30-010 300 10.0 176.3
WICHCX 30-015 450 15.0 117.6
WICHCX 30-020 600 20.0 88.2
WICHCX 30-025 750 25.0 70.5
WICHCX 30-030 900 30.0 58.8
WICHCX 30-040 1200 40.0 44.1
WICHCX 30-050 1500 50.0 35.3
WICHCX 30-060 1800 60.0 29.4
WICHCX 30-070 2100 70.0 25.2
WICHCX 30-080 2400 80.0 22.0
WICHCX 30-100 3000 100.0 17.6
WICHCX 30-120 3600 120.0 14.7
WICHCX 30-140 4200 140.0 12.6

.