UL 1007
Product Code : UL 1007
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e.g. Households, Radio of televisions,Monitor and Control desks.
Share Product
Product Code : UL 1007
These cables are used for internal wiring of switchboards, electronic and electrical equipment, e.g. Households, Radio of televisions,Monitor and Control desks.
Share Product
Standard | UL - Std. 758, CSA C 22.2 No. 210 |
Nominal Voltage | 300V |
Test Voltage | 2 KV |
Test Voltage (Spark Test) | 6 KV |
Temperature Range | Flexible -5°C to +80°C. Fixed installation -20°C to + 80°C |
CSA | AWM I A/B |
Bending Radius | Flexing 10 x cable Ø. Fixed installation 5 x cable Ø |
Cable Construction | Annealed plain or tinned stranded copper conductor. PVC - core insulation according to UL - Standard 1581, Class 43 Tab. 50.182, heat and damp resistant. |
Properties | Conditionally resistant to oils, solvents, acids and dyes. |
Conductor -Anealed Bare Copper (ABC) | Insulation- PVC | Ampacity | Net | |||||||
Gauge | No of | Strand | CSA | Dia. | Max.DC Resistance | Thickness in mm | Wire dia. | of Wire | Weight | |
Srands | dia. in mm | mm2 | mm | Ohms/km`@ 20°C | Nom. | Min. | Nom., mm | Amp. | kg/km | |
AWG 32/7/40 | 7 | 0.08 | 0.03 | 0.23 | 589.2 | 0.38 | 0.33 | 0.99 | 0.3 | 1.1 |
AWG 30/7/38 | 7 | 0.10 | 0.05 | 0.31 | 340.3 | 0.38 | 0.33 | 1.07 | 0.5 | 1.4 |
AWG 28/7/36 | 7 | 0.13 | 0.09 | 0.39 | 211.0 | 0.38 | 0.33 | 1.15 | 0.9 | 1.8 |
AWG 26/7/34 | 7 | 0.16 | 0.14 | 0.49 | 132.9 | 0.38 | 0.33 | 1.25 | 1.4 | 2.4 |
AWG 24/7/32 | 7 | 0.20 | 0.22 | 0.61 | 85.1 | 0.38 | 0.33 | 1.37 | 2.2 | 3.3 |
AWG 22/17/34 | 17 | 0.16 | 0.34 | 0.77 | 54.7 | 0.38 | 0.33 | 1.53 | 3.4 | 4.6 |
AWG 20/16/32 | 16 | 0.20 | 0.50 | 0.93 | 37.2 | 0.38 | 0.33 | 1.69 | 5.0 | 6.3 |
AWG 19/24/33 | 24 | 0.20 | 0.75 | 1.14 | 24.8 | 0.38 | 0.33 | 1.90 | 7.5 | 8.9 |
AWG 18/17/30 | 17 | 0.254 | 0.86 | 1.21 | 21.7 | 0.38 | 0.33 | 1.97 | 8.6 | 10.0 |
AWG 16/26/30 | 26 | 0.254 | 1.32 | 1.50 | 14.2 | 0.38 | 0.33 | 2.26 | 13.2 | 14.6 |